Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
2014-02-26 | 23:30:00 | 2014-02-27 | 00:28:14 | Incorrect |
Subject: | MAO/SONDE/M1 - Temperature Sensor Failure |
---|---|
Affected Datastreams: | maosondewnpnM1.b1 |
Description | It appears that the temperature sensor failed on release of balloon |
Measurements |
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
2014-10-17 | 05:28:00 | 2014-10-17 | 07:18:40 | Note |
Subject: | MAO/SONDE/M1 - Reprocessing Notice (RID 1253) |
---|---|
Affected Datastreams: | maosondewnpnM1.b1 |
Description | See below for details of reprocessing that was completed on 20150121. Original DQR category: 4(Red, Incorrect) ------------------------------------------------------------------------------- The operator incorrectly entered the surface RH value as 10% when it was actually 100%. |
Measurements |
|