DATA REPROCESSED and CORRECTED:
When the ceilometer software was changed from CT-View to CL-View, several firmware configuration changes were made to the model CT25K for consistency with the CL31 at other sites, including the data acquisition interval which was changed from 15 to 16 seconds.
However, the global attribute "averaging_interval" in the ceil datastream was not changed. Reprocessing has corrected the global attribute averaging_interval to reflect this change.
The data were archived in August 2017. Please retrieve the reprocessed data for use in your analysis.
You may find these data using the ARM Discovery tool at the following link:
http://www.archive.arm.gov/discovery/#v/results/s/finst::ceil/ffac::asi.S1
ORIGINAL DQR CATEGORY: Note (Important information about data or metadata )
REPROCESSED and CORRECTED DATA ARCHIVED: 2017-08
REPROCESS IDENTIFICATION NUMBER: RID 1573
---------------------------------------------------
--- ORIGINAL DQR DESCRIPTION ---
---------------------------------------------------
When the ceilometer software was changed from CT-View to CL-View, several firmware configuration changes were made to the model CT25K for consistency with the CL31 at other sites, including the data acquisition interval which was changed from 15 to 16 seconds. However, the global attribute "averaging_interval" in the ceil datastream was not changed.
---------------------------------------------------
--- ORIGINAL DQR SUGGESTIONS ---
---------------------------------------------------
These data can be reprocessed to correct the attribute "averaging_interval" from 11.5 seconds to 16 seconds.
|