DQR ID | Subject | Affected Data Streams | Data Quality Metric |
---|---|---|---|
D140103.2 | SGP/MET/E13 - Ice on wind sensor | sgpmetE13.b1 | Incorrect |
D170221.5 | SGP/MET/STAMP/All - Freezing Rain Event | sgpmetE38.b1 | Note |
D161021.7 | SGP/MET/E13 - False corrected precipitation values | sgpmetE13.b1 | Incorrect |
D170327.3 | SGP/MET/E13 - Present weather detector data incorrect after power outage | sgpmetE13.b1 | Incorrect |
D160203.4 | SGP/MET/E13 - False tips in high winds | sgpmetE13.b1 | Note |
D170123.1 | SGP/MET/E11/E13/E15/E21/E31/E32/E33/E34/E35/E36/E37/E38/E39/E40/E41/E9 - Ice storm affected winds | sgpmetE13.b1 | Incorrect |
D110415.2 | SGP/MET/E13 - PWD data incorrect/missing | sgpmetE13.b1 | Incorrect |
D170828.23 | SGP/MET/E13 - Reprocess: Wrong coefficients used for corrected precipitation data | sgpmetE13.b1 | Incorrect |
D151218.8 | SGP/MET/E13 - Data suspect due to system power issues | sgpmetE13.b1 | Suspect |
D161020.2 | SGP/MET/E13 - Wind Values Incorrect | sgpmetE13.b1 | Incorrect |
D161020.1 | SGP/MET/E13 - Data Spikes | sgpmetE13.b1 | Incorrect |
D151201.2 | SGP ALL INSTRUMENTS - Icing Event | sgp30ebbrE34.b1 | Note |
D170321.8 | SGP/MET/E13 - Temperature/humidity sensor occasionally failed 6-month field calibration checks | sgpmetE13.b1 | Suspect |
D170310.16 | SGP/Central Facility - Power Outage | sgpirt25m20sC1.a0 | Note |
D170531.1 | SGP/MET/E13 - Optical rain gauge data incorrect after power outage | sgpmetE13.b1 | Incorrect |
D170327.5 | SGP/MET/E13 - Optical rain gauge data incorrect after power outage | sgpmetE13.b1 | Incorrect |
D120928.1 | SGP/MET/E13 - Low logger voltage | sgpmetE13.b1 | Suspect |
D170201.1 | SGP/MET/E13 - Optical rain gauge data missing | sgpmetE13.b1 | Missing |
D160104.7 | SGP Site Power Outage Due to Winter Storm | sgpirt200msE13.a1 | Note |
D110419.1 | SGP/MET/E13 - Missing PWD data | sgpmetE13.b1 | Missing |
D170828.24 | SGP/MET/E13 - Reprocess: Wrong coefficients used for corrected precipitation data | sgpmetE13.b1 | Incorrect |
D170420.1 | SGP/MET/E13 - Wind speed incorrect | sgpmetE13.b1 | Incorrect |
D170303.6 | SGP/MET/E13 - Optical rain gauge data parsing error | sgpmetE13.b1 | Incorrect |
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
2013-12-21 | 18:42:00 | 2013-12-23 | 19:40:00 | Incorrect |
Subject: | SGP/MET/E13 - Ice on wind sensor |
---|---|
Affected Datastreams: | sgpmetE13.b1 |
Description | Wind speed and direction are flat-lined due to ice accumulation on the sensor. |
Measurements |
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
2017-01-13 | 10:00:00 | 2017-01-16 | 12:00:00 | Note |
Subject: | SGP/MET/STAMP/All - Freezing Rain Event |
---|---|
Affected Datastreams: | sgpmetE38.b1 |
Description | A freezing rain event potentially affected some of the STAMP and MET tipping bucket rain gauges. The rain accumulation amounts generally agree (2 exceptions noted below) but the timing and rate of precipitation may disagree at times between the STAMP and MET. Instruments at E33 and E39 were found to differ more than the expected uncertainty and will be covered in additional DQRs if a problem is found. |
Measurements |
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
2016-09-23 | 15:20:00 | 2016-09-23 | 15:21:59 | Incorrect |
2016-04-21 | 18:55:00 | 2016-04-21 | 19:05:59 | Incorrect |
2016-06-17 | 13:57:00 | 2016-06-17 | 13:59:59 | Incorrect |
2016-05-05 | 18:30:00 | 2016-05-05 | 18:31:59 | Incorrect |
2016-01-29 | 15:40:00 | 2016-01-29 | 15:41:59 | Incorrect |
2016-06-03 | 16:21:00 | 2016-06-03 | 16:22:59 | Incorrect |
2016-03-11 | 19:07:00 | 2016-03-11 | 19:09:59 | Incorrect |
2016-06-30 | 19:07:00 | 2016-06-30 | 19:12:59 | Incorrect |
2016-02-26 | 15:45:00 | 2016-02-26 | 15:47:59 | Incorrect |
2016-04-07 | 15:54:00 | 2016-04-07 | 15:56:59 | Incorrect |
2016-08-11 | 14:15:00 | 2016-08-11 | 15:00:59 | Incorrect |
2016-02-11 | 19:27:00 | 2016-02-11 | 19:29:59 | Incorrect |
2016-03-25 | 15:22:00 | 2016-03-25 | 15:24:59 | Incorrect |
2016-09-08 | 14:27:00 | 2016-09-08 | 14:29:59 | Incorrect |
2016-08-25 | 19:15:00 | 2016-08-25 | 19:16:59 | Incorrect |
2016-05-20 | 15:45:00 | 2016-05-20 | 15:47:59 | Incorrect |
2016-07-12 | 13:41:00 | 2016-07-12 | 13:43:59 | Incorrect |
Subject: | SGP/MET/E13 - False corrected precipitation values |
---|---|
Affected Datastreams: | sgpmetE13.b1 |
Description | A program bug allowed for maintenance tips to be recorded as precipitation in the tbrg_precip_total_corr variable. |
Measurements |
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
2017-03-06 | 19:51:00 | 2017-03-24 | 18:22:59 | Incorrect |
Subject: | SGP/MET/E13 - Present weather detector data incorrect after power outage |
---|---|
Affected Datastreams: | sgpmetE13.b1 |
Description | A power interruption caused the data logger to read incorrect data from the present weather detector. |
Measurements |
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
1993-07-21 | 00:00:00 | 2016-01-12 | 19:58:00 | Note |
Subject: | SGP/MET/E13 - False tips in high winds |
---|---|
Affected Datastreams: | sgpmetE13.b1 |
Description | The TBRG's were mounted at a height that made them prone to vibrations caused by high winds which may have caused false tips. The end date of this DQR indicates when the rain gauge was lowered to mitigate these effects. Effects on the total precipitation amounts are assumed to be negligible. |
Measurements |
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
2017-01-14 | 00:00:00 | 2017-01-16 | 23:59:59 | Incorrect |
Subject: | SGP/MET/E11/E13/E15/E21/E31/E32/E33/E34/E35/E36/E37/E38/E39/E40/E41/E9 - Ice storm affected winds |
---|---|
Affected Datastreams: | sgpmetE13.b1 |
Description | An ice storm impaired the wind sensor mechanics during this time. At most sites, winds flatlined for a large part of 1/15. Data from 1/14 - 1/16 may not be accurate. |
Measurements |
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
2011-01-15 | 13:00:00 | 2011-02-18 | 22:00:00 | Incorrect |
Subject: | SGP/MET/E13 - PWD data incorrect/missing |
---|---|
Affected Datastreams: | sgpmetE13.b1 |
Description | Data collection problems during the time period specified resulted in incorrect or missing PWD data. |
Measurements |
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
2016-01-29 | 15:40:00 | 2016-10-03 | 23:04:59 | Incorrect |
Subject: | SGP/MET/E13 - Reprocess: Wrong coefficients used for corrected precipitation data |
---|---|
Affected Datastreams: | sgpmetE13.b1 |
Description | The wrong dynamic calibration coefficients were used to correct the raw precipitation data during this time. Data will be reprocessed to correct for this issue. Old R1 = -0.0002 (0) Old R2 = 0.9615 (0.961) New R1 = 0.0002 (0) New R2 = 1.0439 (1.044) |
Measurements |
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
2015-11-30 | 16:54:00 | 2015-12-04 | 15:16:00 | Suspect |
Subject: | SGP/MET/E13 - Data suspect due to system power issues |
---|---|
Affected Datastreams: | sgpmetE13.b1 |
Description | Issues with power supply to the system caused outages and suspect data during this time. |
Measurements |
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
2004-07-26 | 14:08:00 | 2004-07-26 | 14:10:00 | Incorrect |
Subject: | SGP/MET/E13 - Wind Values Incorrect |
---|---|
Affected Datastreams: | sgpmetE13.b1 |
Description | Wind speed is incorrect after coming back online |
Measurements |
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
2004-07-26 | 23:45:00 | 2004-07-27 | 01:00:00 | Incorrect |
Subject: | SGP/MET/E13 - Data Spikes |
---|---|
Affected Datastreams: | sgpmetE13.b1 |
Description | MET went down during some storms and produced some erroneous errors when brought back online. |
Measurements |
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
2015-11-27 | 00:00:00 | 2015-11-30 | 23:59:59 | Note |
Subject: | SGP ALL INSTRUMENTS - Icing Event |
---|---|
Affected Datastreams: | sgp30ebbrE34.b1 |
Description | An icing event (winter storm Cara) passed slowly through the area during this time frame. Instruments at the SGP may have been affected by ice accumulation. |
Measurements |
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
1999-10-07 | 00:00:00 | 2002-06-14 | 23:59:59 | Suspect |
Subject: | SGP/MET/E13 - Temperature/humidity sensor occasionally failed 6-month field calibration checks |
---|---|
Affected Datastreams: | sgpmetE13.b1 |
Description | The temperature/humidity sensor was not calibrated annually during this time. The temperature/humidity readings failed the 6-month field calibration check on four occasions during this period (temperature reading low, humidity reading high). Upon removal, the field calibration check reported the humidity reading was high (+4%). In general, the relative humidity may have been subject to drift during this time. The manufacturer characterizes sensor drift at <1% / year. A detailed summary is available in the ARM technical report: https://www.arm.gov/publications/tech_reports/doe-sc-arm-tr-192.pdf |
Measurements |
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
2017-03-05 | 00:23:01 | 2017-03-09 | 14:30:21 | Note |
Subject: | SGP/Central Facility - Power Outage |
---|---|
Affected Datastreams: | sgpirt25m20sC1.a0 |
Description | Automated scripts show that these instruments were affected by a power outage at the central facility resulting in missing data. Most of the instruments came back online on March 6th but some took longer. |
Measurements |
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
2017-03-23 | 21:28:00 | 2017-05-16 | 18:27:59 | Incorrect |
Subject: | SGP/MET/E13 - Optical rain gauge data incorrect after power outage |
---|---|
Affected Datastreams: | sgpmetE13.b1 |
Description | A power interruption caused the data logger to read incorrect data from the optical rain gauge. |
Measurements |
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
2017-03-06 | 19:51:00 | 2017-03-23 | 21:27:00 | Incorrect |
Subject: | SGP/MET/E13 - Optical rain gauge data incorrect after power outage |
---|---|
Affected Datastreams: | sgpmetE13.b1 |
Description | A power interruption caused the data logger to read incorrect data from the optical rain gauge. |
Measurements |
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
2012-09-08 | 20:52:00 | 2012-09-16 | 14:39:00 | Suspect |
Subject: | SGP/MET/E13 - Low logger voltage |
---|---|
Affected Datastreams: | sgpmetE13.b1 |
Description | Low logger voltage was reported. Low voltage may result in data spikes or dropouts. |
Measurements |
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
2016-10-03 | 16:16:00 | 2017-01-31 | 20:57:00 | Missing |
Subject: | SGP/MET/E13 - Optical rain gauge data missing |
---|---|
Affected Datastreams: | sgpmetE13.b1 |
Description | No optical rain gauge data are available during this time. |
Measurements |
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
2015-12-26 | 00:00:00 | 2016-01-01 | 23:59:59 | Note |
Subject: | SGP Site Power Outage Due to Winter Storm |
---|---|
Affected Datastreams: | sgpirt200msE13.a1 |
Description | On Saturday and Sunday, December 26 and 27th a powerful winter storm (Goliath) brought sleet and freezing rain to much of Oklahoma with wind gusts of 45 MPH at times. The result was very very slick roads and mass power outages. The SGP central facility lost power at 8:55 PM CDT on Sunday, December 27th. The power was restored on 7:56 PM CDT on Wednesday, December 30th Site Emergency procedures were activated and Technicians drained water out of instrument reservoirs and other measures as needed, early Monday morning. On Wednesdays as roads and power started was restored to much of the areas east of I-35 , Site Technicians performed maintenance on several Extended Facilities. During this period, data are potentially missing, incorrect, or suspect. Carefully inspect the data before use. |
Measurements |
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
2010-09-09 | 00:00:00 | 2011-01-10 | 20:00:00 | Missing |
Subject: | SGP/MET/E13 - Missing PWD data |
---|---|
Affected Datastreams: | sgpmetE13.b1 |
Description | PWD data were missing due to an accidental reset on the instrument. |
Measurements |
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
2016-10-03 | 23:04:00 | 2017-08-10 | 15:15:59 | Incorrect |
Subject: | SGP/MET/E13 - Reprocess: Wrong coefficients used for corrected precipitation data |
---|---|
Affected Datastreams: | sgpmetE13.b1 |
Description | The wrong dynamic calibration coefficients were used to correct the raw precipitation data during this time. Data will be reprocessed to correct for this issue. Old SN = 120 New SN = 121 Old R1 = (0) Old R2 = (1.015) New R1 = 0.0002 (0) New R2 = 1.0439 (1.044) |
Measurements |
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
2017-04-06 | 19:10:00 | 2017-04-17 | 15:41:00 | Incorrect |
Subject: | SGP/MET/E13 - Wind speed incorrect |
---|---|
Affected Datastreams: | sgpmetE13.b1 |
Description | A broken wind speed signal wire caused incorrect data during this time. |
Measurements |
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
2017-02-01 | 00:00:00 | 2017-02-22 | 21:44:59 | Incorrect |
Subject: | SGP/MET/E13 - Optical rain gauge data parsing error |
---|---|
Affected Datastreams: | sgpmetE13.b1 |
Description | A data acquisition problem caused incorrect optical rain gauge data to be reported. |
Measurements |
|