Data Quality Report for Order ID: 187781
User ID: mpekour    Date completed: 2017-09-18
All DQRs
DQR ID Subject Affected Data Streams Data Quality Metric
D160520.12 SGP/DL/DLPROF/C1 - Reprocess: Incorrect serial number sgpdlcal2C1.b1 Note
D160520.13 SGP/DL/DLPROF/E32 - Reprocessed and Corrected: Incorrect serial number sgpdlfptE32.b1 Note
D160520.14 SGP/DL/DLPROF/E37 - Reprocessed and Corrected: Incorrect serial number sgpdlppiE37.b1 Note
D160617.10 SGP/DL/C1 - Power supply issue sgpdlfptC1.a0 Missing
 
DQR ID: D160520.12    (Back to Top)
Start Date Start Time End Date End Time Data Quality Metric
2016-05-02 18:00:00 2016-05-19 22:00:00 Note
Subject: SGP/DL/DLPROF/C1 - Reprocess: Incorrect serial number
Affected Datastreams: sgpdlcal2C1.b1
Description The instrument serial number that appears in the netcdf files global attributes is incorrect. The correct serial number is 0116-107.
Measurements
  • base_time (Base time in Epoch)
 
DQR ID: D160520.13    (Back to Top)
Start Date Start Time End Date End Time Data Quality Metric
2016-05-03 18:00:00 2016-05-17 17:00:00 Note
Subject: SGP/DL/DLPROF/E32 - Reprocessed and Corrected: Incorrect serial number
Affected Datastreams: sgpdlfptE32.b1
Description DATA REPROCESSED and CORRECTED: The instrument serial number that appears in the netcdf files global attributes was incorrect. The corrected serial number is 0116-108. The data were archived March 2017. Please retrieve the reprocessed data for use in your analysis. You may find these data using the ARM Discovery tool at the following link: http://www.archive.arm.gov/discovery/#v/results/s/finst::dl/fsite::sgp/ffac::sgp.E32 ORIGINAL DQR CATEGORY: Transparent( Does not affect quality) REPROCESSED and CORRECTED DATA ARCHIVED:2017-03 REPROCESS IDENTIFICATION NUMBER: RID 1466 --------------------------------------------------- --- ORIGINAL DQR DESCRIPTION --- --------------------------------------------------- The instrument serial number that appears in the netcdf files global attributes is incorrect. The correct serial number is 0116-108.
Measurements
  • base_time (Base time in Epoch)
 
DQR ID: D160520.14    (Back to Top)
Start Date Start Time End Date End Time Data Quality Metric
2016-05-03 15:00:00 2016-05-19 22:00:00 Note
Subject: SGP/DL/DLPROF/E37 - Reprocessed and Corrected: Incorrect serial number
Affected Datastreams: sgpdlppiE37.b1
Description DATA REPROCESSED and CORRECTED: The instrument serial number that appears in the netcdf files global attributes is incorrect. The corrected serial number is 0116-109. The data were archived in March 2017. Please retrieve the reprocessed data for use in your analysis. You may find these data using the ARM Discovery tool at the following link: http://www.archive.arm.gov/discovery/#v/results/s/finst::dl/fsite::sgp/ffac::sgp.E37 ORIGINAL DQR CATEGORY: Transparent( Does not affect quality) REPROCESSED and CORRECTED DATA ARCHIVED:2017-03 REPROCESS IDENTIFICATION NUMBER: RID 1467 --------------------------------------------------- --- ORIGINAL DQR DESCRIPTION --- --------------------------------------------------- The instrument serial number that appears in the netcdf files global attributes is incorrect. The correct serial number is 0116-109.
Measurements
  • base_time (Base time in Epoch)
 
DQR ID: D160617.10    (Back to Top)
Start Date Start Time End Date End Time Data Quality Metric
2016-05-27 20:20:00 2016-05-31 16:27:00 Missing
Subject: SGP/DL/C1 - Power supply issue
Affected Datastreams: sgpdlfptC1.a0
Description The supply voltage from the external power supply was running low due to overheating. As a result, the instrument was intentionally shutdown for the long Memorial Day weekend.
Measurements
  • qc_radial_velocity (Quality check results on field: Radial velocity)
  • lon (East longitude)
  • time (Time offset from midnight)
  • time_offset (Time offset from base_time)
  • qc_time (Quality check results on field: Time offset from midnight)
  • lat (North latitude)
  • elevation (Beam elevation)
  • base_time (Base time in Epoch)
  • alt (Altitude above mean sea level)
  • radial_velocity (Radial velocity)
  • range (Distance from Lidar to center of range gate)
  • intensity (Intensity (signal to noise ratio + 1))
  • attenuated_backscatter (Attenuated backscatter)
  • azimuth (Azimuth relative to true north)