DQR ID | Subject | Affected Data Streams | Data Quality Metric |
---|---|---|---|
D121016.2 | SGP/ECOR/E14 - Missing data | sgp30ecorE14.b1 | Missing |
D151209.1 | SGP/ECOR/E14/E21/E31/E33/E37/E38/E39 - Sensible and Latent Heat, and CO2 Fluxes Incorrect | sgp30ecorE38.b1 | Incorrect |
D160212.3 | SGP - Data System Upgrades: Data Missing | sgp30ecorE14.b1 | Missing |
D130913.1 | SGP/ECOR/E14 - CO2 and Latent Heat Fluxes Incorrect | sgp30ecorE14.b1 | Suspect |
D070514.2 | SGP/ECOR/E14 - IRGA Temperature Incorrect or Missing | sgp30ecorE14.b1 | Incorrect |
D120128.3 | SGP/ECOR/E14 - Intermittent missing data | sgp30ecorE14.b1 | Missing |
D051031.3 | SGP/ECOR/E14 - CO2/H2O Incorrect | sgp30ecorE14.b1 | Incorrect |
D151201.2 | SGP ALL INSTRUMENTS - Icing Event | sgp30ecorE14.b1 | Note |
D170217.3 | SGP/ECOR/E14 - Sensible and Latent Heat Fluxes, CO2 Flux, Momentum Flux Incorrect | sgp30ecorE14.b1 | Incorrect |
D140912.1 | SGP/ECOR/E14/E21/E31/E37 - Water Vapor Density differed from MET Measurements | sgp30ecorE31.b1 | Note |
D131209.3 | SGP/ECOR/E14 - Data Missing from Power Outage | sgp30ecorE14.b1 | Missing |
D080604.2 | SGP/ECOR/E14 - Sensor failure | sgp30ecorE14.b1 | Suspect |
D051216.2 | SGP/ECOR/E14 - Flux Measurements Incorrect | sgp30ecorE14.b1 | Incorrect |
D131211.1 | SGP/ECOR/E14 - Latent heat and CO2 flux incorrect | sgp30ecorE14.b1 | Incorrect |
D070223.1 | SGP/ECOR/E14 - Fluxes and Most Measurements Incorrect | sgp30ecorE14.b1 | Incorrect |
D160104.7 | SGP Site Power Outage Due to Winter Storm | sgpirt200msE13.a1 | Note |
D121001.1 | SGP/ECOR/E14 - Intermittent missing data | sgp30ecorE14.b1 | Missing |
D170703.2 | SGP/ECOR/E14 - Data Missing | sgp30ecorE14.b1 | Missing |
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
2012-10-05 | 19:30:00 | 2012-10-09 | 18:00:00 | Missing |
Subject: | SGP/ECOR/E14 - Missing data |
---|---|
Affected Datastreams: | sgp30ecorE14.b1 |
Description | Data are missing and unrecoverable. |
Measurements |
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
2015-11-26 | 12:30:00 | 2015-11-30 | 15:30:00 | Incorrect |
Subject: | SGP/ECOR/E14/E21/E31/E33/E37/E38/E39 - Sensible and Latent Heat, and CO2 Fluxes Incorrect |
---|---|
Affected Datastreams: | sgp30ecorE38.b1 |
Description | Icing conditions caused sensible and latent heat fluxes and CO2 flux to be incorrect during much of this period. |
Measurements |
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
2016-01-26 | 18:00:00 | 2016-01-27 | 21:45:59 | Missing |
Subject: | SGP - Data System Upgrades: Data Missing |
---|---|
Affected Datastreams: | sgp30ecorE14.b1 |
Description | The data system was undergoing upgrades. Data were lost during this period. |
Measurements |
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
2013-09-08 | 22:00:00 | 2013-09-13 | 14:30:00 | Suspect |
Subject: | SGP/ECOR/E14 - CO2 and Latent Heat Fluxes Incorrect |
---|---|
Affected Datastreams: | sgp30ecorE14.b1 |
Description | Various data values from the CO2/H2O instrument were missing at different times. |
Measurements |
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
2007-05-09 | 13:00:00 | 2007-05-19 | 17:00:00 | Incorrect |
Subject: | SGP/ECOR/E14 - IRGA Temperature Incorrect or Missing |
---|---|
Affected Datastreams: | sgp30ecorE14.b1 |
Description | The temp_irga was too large 05/09/07 1300 GMT - 05/10/07 2000 GMT. The temp_irga was flat lined at 49.96 C 05/10/07 2030 GMT - 05/17/07 2000 GMT. The temp_irga was missing 05/17/07 2030 GMT - 05/19/07 1700 GMT. |
Measurements |
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
2011-08-04 | 13:30:00 | 2011-11-29 | 21:00:00 | Missing |
Subject: | SGP/ECOR/E14 - Intermittent missing data |
---|---|
Affected Datastreams: | sgp30ecorE14.b1 |
Description | Many times during a month there was missing data because of a failing UPS. |
Measurements |
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
2005-08-25 | 00:00:00 | 2005-08-29 | 02:30:00 | Incorrect |
Subject: | SGP/ECOR/E14 - CO2/H2O Incorrect |
---|---|
Affected Datastreams: | sgp30ecorE14.b1 |
Description | The LI-7500 CO2/H2O sensor stopped working after a rainstorm. CO2 and H2O data are incorrect during the stated period. |
Measurements |
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
2015-11-27 | 00:00:00 | 2015-11-30 | 23:59:59 | Note |
Subject: | SGP ALL INSTRUMENTS - Icing Event |
---|---|
Affected Datastreams: | sgp30ecorE14.b1 |
Description | An icing event (winter storm Cara) passed slowly through the area during this time frame. Instruments at the SGP may have been affected by ice accumulation. |
Measurements |
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
2017-01-13 | 18:30:00 | 2017-01-16 | 11:30:00 | Incorrect |
Subject: | SGP/ECOR/E14 - Sensible and Latent Heat Fluxes, CO2 Flux, Momentum Flux Incorrect |
---|---|
Affected Datastreams: | sgp30ecorE14.b1 |
Description | Sensible and latent heat flux, CO2 flux, and momentum flux, plus supporting measurements were incorrect because of an ice storm. |
Measurements |
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
2014-08-01 | 00:00:00 | 2014-09-04 | 17:00:00 | Note |
Subject: | SGP/ECOR/E14/E21/E31/E37 - Water Vapor Density differed from MET Measurements |
---|---|
Affected Datastreams: | sgp30ecorE31.b1 |
Description | ECOR Water Vapor Density differed from that measured by the MET system. ECOR latent heat fluxes were not affected. |
Measurements |
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
2013-11-23 | 04:30:00 | 2013-11-25 | 15:30:00 | Missing |
Subject: | SGP/ECOR/E14 - Data Missing from Power Outage |
---|---|
Affected Datastreams: | sgp30ecorE14.b1 |
Description | All data is missing during the period. The systems UPS failed and was replaced at 1620 GMT on 11/25/13. Data collection resumed at 1600 GMT on 11/25/13. |
Measurements |
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
2008-04-02 | 13:30:00 | 2008-06-05 | 19:30:00 | Suspect |
Subject: | SGP/ECOR/E14 - Sensor failure |
---|---|
Affected Datastreams: | sgp30ecorE14.b1 |
Description | The water vapor output of the LI-7500 was too low, indicating that water vapor leaked into the sensor and that the chemicals are spent or there was an electronic failure. Latent heat flux was not normally affected by this problem. |
Measurements |
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
2006-05-05 | 21:00:00 | 2006-06-13 | 14:00:00 | Incorrect |
2006-01-24 | 15:00:00 | 2006-02-13 | 19:30:00 | Incorrect |
2005-11-04 | 13:30:00 | 2005-11-17 | 16:30:00 | Incorrect |
2005-12-01 | 19:30:00 | 2005-12-13 | 16:30:00 | Incorrect |
2006-07-07 | 19:30:00 | 2006-07-14 | 15:00:00 | Incorrect |
Subject: | SGP/ECOR/E14 - Flux Measurements Incorrect |
---|---|
Affected Datastreams: | sgp30ecorE14.b1 |
Description | The ECOR datastream was corrupted; this happens when the ECOR program produces a datastream of the wrong length (i.e., leaves one or more measurements out). Fluxes and some other measurements are incorrect. Reprocessing will not correct this problem; the raw data are corrupted. |
Measurements |
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
2013-11-25 | 16:30:00 | 2013-11-27 | 17:00:00 | Incorrect |
Subject: | SGP/ECOR/E14 - Latent heat and CO2 flux incorrect |
---|---|
Affected Datastreams: | sgp30ecorE14.b1 |
Description | Latent heat flux and CO2 flux were incorrect for a couple of days following a power outage. |
Measurements |
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
2007-01-14 | 05:00:00 | 2007-02-02 | 16:00:00 | Incorrect |
Subject: | SGP/ECOR/E14 - Fluxes and Most Measurements Incorrect |
---|---|
Affected Datastreams: | sgp30ecorE14.b1 |
Description | The ECOR system was having major problems during this period and most measurements were incorrect most of the time. |
Measurements |
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
2015-12-26 | 00:00:00 | 2016-01-01 | 23:59:59 | Note |
Subject: | SGP Site Power Outage Due to Winter Storm |
---|---|
Affected Datastreams: | sgpirt200msE13.a1 |
Description | On Saturday and Sunday, December 26 and 27th a powerful winter storm (Goliath) brought sleet and freezing rain to much of Oklahoma with wind gusts of 45 MPH at times. The result was very very slick roads and mass power outages. The SGP central facility lost power at 8:55 PM CDT on Sunday, December 27th. The power was restored on 7:56 PM CDT on Wednesday, December 30th Site Emergency procedures were activated and Technicians drained water out of instrument reservoirs and other measures as needed, early Monday morning. On Wednesdays as roads and power started was restored to much of the areas east of I-35 , Site Technicians performed maintenance on several Extended Facilities. During this period, data are potentially missing, incorrect, or suspect. Carefully inspect the data before use. |
Measurements |
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
2012-09-04 | 21:00:00 | 2012-09-19 | 20:00:00 | Missing |
Subject: | SGP/ECOR/E14 - Intermittent missing data |
---|---|
Affected Datastreams: | sgp30ecorE14.b1 |
Description | The ecor computer at E14 locked up. Cooling fans were replaced, and the computer was returned to service and collecting data. Some data loss has occurred after the computer was virtualized, but data loss has not occurred recently. The data losses were intermittent during short periods of time within the date/time range. |
Measurements |
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
2017-03-05 | 14:00:00 | 2017-03-06 | 20:00:00 | Missing |
Subject: | SGP/ECOR/E14 - Data Missing |
---|---|
Affected Datastreams: | sgp30ecorE14.b1 |
Description | Data missing during this period. |
Measurements |
|