Data Quality Report for Order ID: 188005
User ID: dolinare2    Date completed: 2017-09-29
All DQRs
DQR ID Subject Affected Data Streams Data Quality Metric
D101218.1 TWP/QCRAD/C2 - Instrument grounding problem twpqcrad1longC2.s1 Incorrect
D120606.4 TWP/QCRAD/C2 - Case and dome temperatures noisy or bad twpqcrad1longC2.s2 Suspect
D120607.2 TWP/QCRAD/C2 - Direct normal reading too low twpqcrad1longC2.c1 Incorrect
D101026.1 TWP/QCRAD/C1/C2/C3 - error in qc flags twpqcrad1longC3.c1 Note
D120607.1 TWP/QCRAD/C2 - NIP cable bad twpqcrad1longC2.c1 Incorrect
D120607.3 TWP/QCRAD/C2 - Tracker failure twpqcrad1longC2.c2 Incorrect
 
DQR ID: D101218.1    (Back to Top)
Start Date Start Time End Date End Time Data Quality Metric
2009-05-04 00:00:00 2009-05-08 23:59:00 Incorrect
2009-05-21 18:55:00 2009-05-25 21:00:00 Incorrect
2009-04-23 00:00:00 2009-04-23 23:59:00 Incorrect
2009-05-15 00:00:00 2009-05-15 23:59:00 Incorrect
Subject: TWP/QCRAD/C2 - Instrument grounding problem
Affected Datastreams: twpqcrad1longC2.s1
Description A grounding problem with the skyrad data logger (discussed in DQR D090605.2) created intermittent anomalous voltages and incorrect data. Days listed in this DQR are periods where bad data could be clearly identified; data from other days in this date range should be treated with caution.
Measurements
  • LWupTc (Upwelling LW Case Temperature)
  • up_short_hemisp (Upwelling Shortwave Hemispheric Irradiance)
  • BestEstimate_down_short_hemisp (Best Estimate Global Downwelling Shortwave Hemispheric Irradiance)
  • up_long_hemisp (Upwelling (10 meter) Longwave Hemispheric Irradiance)
  • LWdnTd (Downwelling LW Dome Temperature)
  • short_direct_normal (Shortwave Direct Normal Irradiance)
  • down_short_diffuse_hemisp (Downwelling Shortwave Diffuse Hemispheric Irradiance)
  • down_long_hemisp (Downwelling Longwave Hemispheric Irradiance)
  • down_short_hemisp (IR corrected Global Downwelling Shortwave Hemispheric Irradiance)
  • LWdnTc (Downwelling LW Case Temperature)
  • LWupTd (Upwelling LW Dome Temperature)
 
DQR ID: D120606.4    (Back to Top)
Start Date Start Time End Date End Time Data Quality Metric
2009-04-15 00:00:00 2009-06-01 00:00:00 Suspect
2001-05-17 00:00:00 2003-03-03 21:00:00 Suspect
2006-11-10 12:00:00 2006-11-26 23:00:00 Suspect
Subject: TWP/QCRAD/C2 - Case and dome temperatures noisy or bad
Affected Datastreams: twpqcrad1longC2.s2
Description Upwelling and downwelling longwave case and dome temperatures are noisy or bad during this time. Not all corrections and tests can be applied to LW fluxes as a result. No instrument DQRs exist describing this problem.
Measurements
  • LWupTc (Upwelling LW Case Temperature)
  • up_long_hemisp (Upwelling (10 meter) Longwave Hemispheric Irradiance)
  • LWdnTd (Downwelling LW Dome Temperature)
  • down_long_hemisp (Downwelling Longwave Hemispheric Irradiance)
  • LWdnTc (Downwelling LW Case Temperature)
  • LWupTd (Upwelling LW Dome Temperature)
 
DQR ID: D120607.2    (Back to Top)
Start Date Start Time End Date End Time Data Quality Metric
2008-03-02 22:30:00 2008-03-10 21:30:00 Incorrect
Subject: TWP/QCRAD/C2 - Direct normal reading too low
Affected Datastreams: twpqcrad1longC2.c1
Description Direct normal irradiance data is bad. Described in instrument DQR D080313.2.
Measurements
  • short_direct_normal (Shortwave Direct Normal Irradiance)
 
DQR ID: D101026.1    (Back to Top)
Start Date Start Time End Date End Time Data Quality Metric
2002-03-12 00:00:00 2010-06-07 23:59:00 Note
Subject: TWP/QCRAD/C1/C2/C3 - error in qc flags
Affected Datastreams: twpqcrad1longC3.c1
Description In the qc_down_short_diffuse_hemisp field, QC failures from the test indicated by bit_13, "data failed tracker off test", were set incorrectly as bit_9, "GSW2SumSW (93 > SZA > 75 and SumSW > 50; GSW/SumSW < 0.85 or GSW/SumSW > 1.15)". Solar tracker failures are correctly indicated in the aqc_down_short_diffuse_hemisp field. In the qc_short_direct_normal field, QC failures from the test indicated by bit_10, "data failed tracker off test", were set incorrectly as bit_9, "GSW2SumSW (93 > SZA > 75 and SumSW > 50; GSW/ SumSW < 0.85 or GSW/SumSW > 1.15)". Solar tracker failures are correctly indicated in the aqc_short_direct_normal field. This is a software problem in the VAP that impacts all dates for which a solar tracker failure occurred prior to 20100608 for each facility. The 20020312 start date was chosen because the DQR system can not link multiple start/end date/times with multiple facilities within the same report. As a result, the latest start date corresponding to C3 was chosen. The actual start dates for which this problem could have occurred for each facility are as follows: C1: 19961010 C2: 19981029 C3: 20020312 Please note that if a solar tracker failure is not indicated by the aqc_down_short_diffuse_hemisp and/or aqc_short_direct_normal fields you can ignore this DQR.
Measurements
  • short_direct_normal (Shortwave Direct Normal Irradiance)
  • down_short_diffuse_hemisp (Downwelling Shortwave Diffuse Hemispheric Irradiance)
 
DQR ID: D120607.1    (Back to Top)
Start Date Start Time End Date End Time Data Quality Metric
2007-01-31 02:23:00 2007-02-10 00:55:00 Incorrect
Subject: TWP/QCRAD/C2 - NIP cable bad
Affected Datastreams: twpqcrad1longC2.c1
Description Shortwave direct normal irradiance data are missing or incorrect due to instrument cable failure. Described in instrument DQR D070206.1. Note that fewer quality checks can be applied accurately to the BestEstimate data.
Measurements
  • short_direct_normal (Shortwave Direct Normal Irradiance)
 
DQR ID: D120607.3    (Back to Top)
Start Date Start Time End Date End Time Data Quality Metric
2008-12-17 19:42:00 2008-12-21 22:15:00 Incorrect
2001-05-26 12:00:00 2001-06-18 04:00:00 Incorrect
2009-03-25 20:00:00 2009-05-18 04:42:00 Incorrect
1999-09-01 00:00:00 1999-11-01 00:00:00 Incorrect
2003-12-01 00:00:00 2004-01-01 00:00:00 Incorrect
2011-10-06 00:00:00 2011-12-31 00:00:00 Incorrect
2011-06-16 23:35:00 2011-08-15 01:30:00 Incorrect
2001-06-25 18:00:00 2001-08-16 04:00:00 Incorrect
Subject: TWP/QCRAD/C2 - Tracker failure
Affected Datastreams: twpqcrad1longC2.c2
Description Tracker appears to be out of alignment or inoperative during these times. The short_direct_normal (NIP) and down_short_diffuse_hemisp (8-48) data appear to be bad and not recoverable. Several of these periods are documented in instrument DQRs: D110831.1, D090328.1, D081222.3, D040107.1, D011207.1, D011019.8
Measurements
  • BestEstimate_down_short_hemisp (Best Estimate Global Downwelling Shortwave Hemispheric Irradiance)
  • short_direct_normal (Shortwave Direct Normal Irradiance)
  • down_short_diffuse_hemisp (Downwelling Shortwave Diffuse Hemispheric Irradiance)