Data Quality Report for Order ID: 188047
User ID: wlj    Date completed: 2017-10-03
All DQRs
DQR ID Subject Affected Data Streams Data Quality Metric
D051114.3 TWP/SKYRAD/C3 - tracker inoperative twpskyradC3.00 Incorrect
D050104.1 TWP/SKYRAD/C3 - Reprocessed and Corrected: NIP calibrations incorrect twpskyradC3.00 Note
 
DQR ID: D051114.3    (Back to Top)
Start Date Start Time End Date End Time Data Quality Metric
2005-11-14 04:53:00 2005-12-02 00:00:00 Incorrect
Subject: TWP/SKYRAD/C3 - tracker inoperative
Affected Datastreams: twpskyradC3.00
Description A lightning strike at Darwin removed the tracker from service. Instruments installed on the tracker were rendered either inoperative or were not shaded during this time period. The longwave hemispheric instruments PIR1 and PIR2 appear to have been unaffected. They are not suseptable to incorrect tracker operation. The downwelling hemispheric shortwave PSP instrument mounted on Skyrad will not be affected by incorrect tracker operation.
Measurements
  • Raw data stream - documentation not supported (Raw data stream - documentation not supported)
 
DQR ID: D050104.1    (Back to Top)
Start Date Start Time End Date End Time Data Quality Metric
2004-05-20 00:00:00 2004-09-02 04:00:00 Note
Subject: TWP/SKYRAD/C3 - Reprocessed and Corrected: NIP calibrations incorrect
Affected Datastreams: twpskyradC3.00
Description DATA REPROCESSED and CORRECTED: During installation of the new Campbell datalogger system and associated program, the NIP (S/N 33551E6) was assigned an incorrect calibration coefficient. A coefficient of 116.01 W/m2/mV was applied when it should have been 124.378 W/m2/mV. The correct calibration coefficient has now been applied. The data were archived April 2017. Please retrieve the reprocessed data for use in your analysis. You may find these data using the ARM Discovery tool at the following link: http://www.archive.arm.gov/discovery/#v/results/s/finst::skyrad/fsite::twp/ffac::twp.C3 ORIGINAL DQR CATEGORY: Red( Incorrect) REPROCESSED and CORRECTED DATA ARCHIVED:2017-04 REPROCESS IDENTIFICATION NUMBER: RID 184 --------------------------------------------------- --- ORIGINAL DQR DESCRIPTION --- --------------------------------------------------- On 05/20 during installtion of the new Campbell datalogger system and associated program the NIP (S/N 33551E6) was assigned an incorrect calibration coefficient. A coefficient of 116.01 W/m2/mV was applied when it should have been 124.378 W/m2/mV. TWP reports SV0405D and SV0409D detail the activities which lead to this DQR.
Measurements
  • Raw data stream - documentation not supported (Raw data stream - documentation not supported)